Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 249
Filtrar
1.
J Med Internet Res ; 26: e45545, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38630535

RESUMO

BACKGROUND: Fundus photography is the most important examination in eye disease screening. A facilitated self-service eye screening pattern based on the fully automatic fundus camera was developed in 2022 in Shanghai, China; it may help solve the problem of insufficient human resources in primary health care institutions. However, the service quality and residents' preference for this new pattern are unclear. OBJECTIVE: This study aimed to compare the service quality and residents' preferences between facilitated self-service eye screening and traditional manual screening and to explore the relationships between the screening service's quality and residents' preferences. METHODS: We conducted a cross-sectional study in Shanghai, China. Residents who underwent facilitated self-service fundus disease screening at one of the screening sites were assigned to the exposure group; those who were screened with a traditional fundus camera operated by an optometrist at an adjacent site comprised the control group. The primary outcome was the screening service quality, including effectiveness (image quality and screening efficiency), physiological discomfort, safety, convenience, and trustworthiness. The secondary outcome was the participants' preferences. Differences in service quality and the participants' preferences between the 2 groups were compared using chi-square tests separately. Subgroup analyses for exploring the relationships between the screening service's quality and residents' preference were conducted using generalized logit models. RESULTS: A total of 358 residents enrolled; among them, 176 (49.16%) were included in the exposure group and the remaining 182 (50.84%) in the control group. Residents' basic characteristics were balanced between the 2 groups. There was no significant difference in service quality between the 2 groups (image quality pass rate: P=.79; average screening time: P=.57; no physiological discomfort rate: P=.92; safety rate: P=.78; convenience rate: P=.95; trustworthiness rate: P=.20). However, the proportion of participants who were willing to use the same technology for their next screening was significantly lower in the exposure group than in the control group (P<.001). Subgroup analyses suggest that distrust in the facilitated self-service eye screening might increase the probability of refusal to undergo screening (P=.02). CONCLUSIONS: This study confirms that the facilitated self-service fundus disease screening pattern could achieve good service quality. However, it was difficult to reverse residents' preferences for manual screening in a short period, especially when the original manual service was already excellent. Therefore, the digital transformation of health care must be cautious. We suggest that attention be paid to the residents' individual needs. More efficient man-machine collaboration and personalized health management solutions based on large language models are both needed.


Assuntos
Idioma , Humanos , Estudos Transversais , China , Modelos Logísticos
2.
Digit Health ; 10: 20552076231207582, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38425654

RESUMO

Purpose: Color fundus photography is widely used in clinical and screening settings for eye diseases. Poor image quality greatly affects the reliability of further evaluation and diagnosis. In this study, we developed an automated assessment module for color fundus photography image quality assessment using deep learning. Methods: A total of 55,931 color fundus photography images from multiple centers in Shanghai and the public database were collected and annotated as training, validation, and testing data sets. The pre-diagnosis image quality assessment module based on the multi-task deep neural network was designed. The detailed criterion of color fundus photography image quality including three subcategories with three levels of grading was applied to improve precision and objectivity. The auxiliary tasks such as the localization of the optic nerve head and macula, the classification of laterality, and the field of view were also included to assist the quality assessment. Finally, we validated our module internally and externally by evaluating the area under the receiver operating characteristic curve, sensitivity, specificity, accuracy, and quadratic weighted Kappa. Results: The "Location" subcategory achieved area under the receiver operating characteristic curves of 0.991, 0.920, and 0.946 for the three grades, respectively. The "Clarity" subcategory achieved area under the receiver operating characteristic curves of 0.980, 0.917, and 0.954 for the three grades, respectively. The "Artifact" subcategory achieved area under the receiver operating characteristic curves of 0.976, 0.952, and 0.986 for the three grades, respectively. The accuracy and Kappa of overall quality reach 88.15% and 89.70%, respectively, on the internal set. These two indicators on the external set were 86.63% and 88.55%, respectively, which were very close to that of the internal set. Conclusions: This work showed that our deep module was able to evaluate the color fundus photography image quality using more detailed three subcategories with three grade criteria. The promising results on both internal and external validation indicated the strength and generalizability of our module.

3.
Biomed Eng Online ; 23(1): 32, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38475784

RESUMO

PURPOSE: This study aimed to investigate the imaging repeatability of self-service fundus photography compared to traditional fundus photography performed by experienced operators. DESIGN: Prospective cross-sectional study. METHODS: In a community-based eye diseases screening site, we recruited 65 eyes (65 participants) from the resident population of Shanghai, China. All participants were devoid of cataract or any other conditions that could potentially compromise the quality of fundus imaging. Participants were categorized into fully self-service fundus photography or traditional fundus photography group. Image quantitative analysis software was used to extract clinically relevant indicators from the fundus images. Finally, a statistical analysis was performed to depict the imaging repeatability of fully self-service fundus photography. RESULTS: There was no statistical difference in the absolute differences, or the extents of variation of the indicators between the two groups. The extents of variation of all the measurement indicators, with the exception of the optic cup area, were below 10% in both groups. The Bland-Altman plots and multivariate analysis results were consistent with results mentioned above. CONCLUSIONS: The image repeatability of fully self-service fundus photography is comparable to that of traditional fundus photography performed by professionals, demonstrating promise in large-scale eye disease screening programs.


Assuntos
Serviços de Saúde Comunitária , Glaucoma , Humanos , Estudos Transversais , Estudos Prospectivos , China , Fotografação/métodos , Fundo de Olho
4.
Lipids Health Dis ; 23(1): 75, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38468242

RESUMO

BACKGROUND: The association between remnant cholesterol (RC) and diabetic retinopathy (DR) in type 2 diabetes mellitus (T2DM) remains unclear. Morphological changes in retinal vessels have been reported to predict vascular complications of diabetes, including DR. METHODS: This cross-sectional study included 6535 individuals with T2DM. The RC value was calculated using the recognized formula. The retinal vascular parameters were measured using fundus photography. The independent relationship between RC and DR was analyzed using binary logistic regression models. Multiple linear regression and subgroup analyses were employed to investigate the link between RC and vascular parameters, including the retinal arteriolar diameter (CRAE), venular diameter (CRVE), and fractal dimension (Df). Mediation analysis was performed to assess whether the vascular morphology could explain the association between RC and DR. RESULTS: RC was independently associated with DR in patients with a longer duration of T2DM (> 7 years). Patients with the highest quartile RC levels had larger CRAE (5.559 [4.093, 7.025] µm), CRVE (7.620 [5.298, 9.941] µm) and Df (0.013 [0.009, 0.017]) compared with patients with the lowest quartile RC levels. Results were robust across different subgroups. The association between RC and DR was mediated by CRVE (0.020 ± 0.005; 95% confidence interval: 0.012-0.032). CONCLUSIONS: RC may be a risk factor for DR among those who have had T2DM for a longer period of time. Higher RC levels were correlated with wider retinal arterioles and venules as well as higher Df, and it may contribute to DR through the dilation of retinal venules.


Assuntos
Diabetes Mellitus Tipo 2 , Retinopatia Diabética , Humanos , Diabetes Mellitus Tipo 2/complicações , Retinopatia Diabética/complicações , Estudos Transversais , Fatores de Risco , Vasos Retinianos/diagnóstico por imagem , Colesterol
5.
Adv Ophthalmol Pract Res ; 4(1): 15-22, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38327667

RESUMO

•Neurodegeneration precede microcirculatory deterioration in DR. Early signs can be seen in DM patients without visible DR symptoms, such as glial cell apoptosis and thinner retinal nerve fiber layer.•Peripapillary microvascular abnormalities in the peripapillary region may affect the normal metabolism of neurons and eventually aggravate the process of DR.•Prompting ongoing research to monitor the peripapillary microcirculation and microvasculature among T1DM children for early detection and prevention.•In longitudinal observation, the vessel density of the peripapillary superficial capillary plexus were slightly affected, while vessel density, blood flow, vessel morphological abnormalities and flow impairment area were significantly deteriorated in the deep capillary plexus.•The peripapillary deep capillary plexus is more susceptible and vulnerable to DR progression and could be used as a target for DR screening.

6.
BMC Ophthalmol ; 24(1): 52, 2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38308203

RESUMO

BACKGROUND: To investigate whether iris blood flow and iris thickness at the iris smooth muscle region affect the pupil diameter at rest and after drug-induced mydriasis in patients with type 1 diabetes mellitus (T1DM) and type 2 diabetes mellitus (T2DM). METHODS: T1DM patients and healthy children were recruited from the SCADE cohort. T2DM patients and healthy adults were recruited from patients undergoing cataract surgery at Shanghai General Hospital. Iris vessel density, pupil diameter (PD) and iris thickness were measured in both the resting and drug-induced mydriasis states. Iris vessel density was measured by optical coherence tomography angiography (OCTA), PD was measured by a pupilometer, and iris thickness at the iris smooth muscle regions were measured using anterior segment optical coherence tomography (AS-OCT). RESULTS: The study included 34 pediatric T1DM patients and 50 adult T2DM patients, both groups without diabetic retinopathy, and age-sex-matched healthy controls. At baseline, T1DM children and healthy children showed no differences in iris blood flow, iris thickness, or PD. However, the adult T2DM group exhibited higher vessel density at the pupil margin, thinner iris thickness at the iris dilator region, and smaller PD compared to healthy adults, with these differences being statistically significant (P < 0.05). After pupil dilation, there were no changes in iris blood flow and PD in the T1DM group compared to healthy children, whereas the T2DM group showed a significantly smaller PD compared to healthy adults. Multivariate regression analysis revealed that in the T2DM group, glycated hemoglobin was an independent factor of PD after dilation (ß=-0.490, p = 0.031), with no such factors identified in the T1DM group. CONCLUSION: The insufficiently dilated pupil diameter after drug-induced mydriasis is correlated to the level of glycated hemoglobin among T2DM patients. TRIAL REGISTRATION: The registration number on the clinical trial website was NCT03631108.


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Midríase , Adulto , Criança , Humanos , China , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 2/complicações , Dilatação Patológica , Hemoglobinas Glicadas , Pressão Intraocular , Iris , Midríase/induzido quimicamente , Pupila/fisiologia , Tomografia de Coerência Óptica , Masculino , Feminino
7.
BMC Microbiol ; 24(1): 19, 2024 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-38200418

RESUMO

BACKGROUND: This study investigates the variations in microbiome abundance and diversity on the ocular surfaces of diabetic patients suffering from dry eye within a community setting. The goal is to offer theoretical insights for the community-level prevention and treatment of dry eye in diabetic cohorts. METHODS: Dry eye screening was performed in the Shanghai Cohort Study of Diabetic Eye Disease (SCODE) from July 15, 2021, to August 15, 2021, in the Xingjing community; this study included both a population with diabetes and a normal population. The population with diabetes included a dry eye group (DM-DE, n = 40) and a non-dry eye group (DM-NoDE, n = 39). The normal population included a dry eye group (NoDM-DE, n = 40) and a control group (control, n = 39). High-throughput sequencing of the 16 S rRNA V3-V4 region was performed on conjunctival swab from both eyes of each subject, and the composition of microbiome on the ocular surface of each group was analyzed. RESULTS: Significant statistical differences were observed in both α and ß diversity of the ocular surface microbiome among the diabetic dry eye, diabetic non-dry eye, non-diabetic dry eye, and normal control groups (P < 0.05). CONCLUSIONS: The study revealed distinct microecological compositions on the ocular surfaces between the diabetic dry eye group and other studied groups. Firmicutes and Anoxybacillus were unique bacterial phyla and genera in the dry eye with DM group, while Actinobacteria and Corynebacterium were unique bacterial phyla and genera in the normal control group.


Assuntos
Diabetes Mellitus , Síndromes do Olho Seco , Microbiota , Humanos , Estudos de Coortes , China
8.
Clin Exp Optom ; 107(1): 58-65, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37078165

RESUMO

CLINICAL RELEVANCE: Anisometropia can affect visual development in children. Investigations of anisometropia in high myopes would explore potential causes related to anisometropia, highlighting the management of anisometropia in high myopia. BACKGROUND: The prevalence of anisometropia ranged from 0.6% to 4.3% in general paediatric population and from 7% to 14% in myopes. Anisometropia is regarded as an associated factor for myopia development, while myopia progression is a stimulus driving anisometropic development. The purpose of this study was to investigate the prevalence of anisometropia and its association with refraction development in Chinese children with high myopia. METHODS: In the cohort study, a total of 1,577 highly myopic (spherical equivalent ≤-5.0D) children aged 4-18 years were included. Refractive parameters (dioptre of sphere, dioptre of cylinder, corneal curvature radius, and axial length) of both eyes were measured after cycloplegia. The prevalence and degree of anisometropia were compared among refractive groups (non-parametric tests or chi-square tests), and regression analyses were used to determine associated factors of anisometropia. The statistical significance was set to P < 0.05 (two-tailed). RESULTS: In highly myopic children with a mean (standard deviation) age of 13.06 (2.80) years, the proportions of spherical equivalent anisometropia, cylindrical anisometropia and spherical anisometropia ≥1.00 D were 34.5%, 21.9% and 39.9%, respectively. There was more spherical equivalent anisometropia associated with more severe astigmatism (P for trend <0.001). In the multivariate regression analysis, more spherical equivalent anisometropia, cylindrical anisometropia and spherical anisometropia were associated with higher degrees of astigmatism (standard beta = -0.175, -0.148 and -0.191, respectively). More spherical anisometropia was associated with better spherical power (standard beta = 0.116). CONCLUSION: The proportion of anisometropia in highly myopic children was high, compared with previously reported general population, and more severe anisometropia was associated with higher degree of cylindrical power, but not spherical power.


Assuntos
Anisometropia , Astigmatismo , Miopia , Humanos , Criança , Anisometropia/epidemiologia , Anisometropia/complicações , Estudos de Coortes , Refração Ocular , Miopia/epidemiologia , Comprimento Axial do Olho
9.
Graefes Arch Clin Exp Ophthalmol ; 262(1): 295-303, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37410179

RESUMO

PURPOSE: To describe the association of refraction development and axial length (AL) in young children and provide new insights into the progression of cylinder power. METHODS: Children (2-3 grades) were enrolled from primary schools in Shanghai and followed up for two years. Cycloplegic refraction, AL, and corneal curvature radius were measured. Refraction parameters were compared among groups with different AL, AL1 (AL < 23.5 mm), AL2 (23.5 mm ≤ AL < 24.5 mm), and AL3 (AL ≥ 24.5 mm). Multiple regression analysis was used to explore risk factors of diopter of cylinder (DC) progression. RESULTS: In total, out of 6891 enrolled children, 5961 participants (7-11 yrs) were included in the final analysis. Over the two-year period, the cylinder power significantly changed, and those with longer AL had more rapid DC progression over the two years (AL1, -0.09 ± 0.35 D; AL2, -0.15 ± 0.39 D; AL3, -0.29 ± 0.44 D) (P < 0.001). The change in DC was independently associated with AL at baseline (P < 0.001). The proportion of with-the-rule astigmatism increased from 91.3% to 92.1% in AL1 group, from 89.1% to 91.8% in AL2 group and from 87.1% to 92.0% in AL3 group. CONCLUSIONS: Young children with long AL experienced rapid progression of cylinder power. Both the control of myopia progression and attention to the correction of astigmatism are necessary in the health management of children with long AL. The significantly increased AL in participants might contribute to both the extent and direction of astigmatism.


Assuntos
Astigmatismo , Criança , Humanos , Pré-Escolar , Seguimentos , Progressão da Doença , China , Refração Ocular , Comprimento Axial do Olho
10.
Graefes Arch Clin Exp Ophthalmol ; 262(2): 651-661, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37578514

RESUMO

PURPOSE: To investigate the effectiveness and cutoffs of axial length/corneal radius (AL/CR) ratio for myopia detection in children by age. METHODS: Totally, 21 kindergartens and schools were enrolled. Non-cycloplegic autorefraction (NCAR), axial length (AL), horizontal and vertical meridian of corneal radius (CR1, CR2), and cycloplegic autorefraction were measured. Receiver operating characteristic (ROC) curve was used to obtain the effectiveness and cutoff for myopia detection. RESULTS: Finally, 7803 participants aged 3-18 years with mean AL/CR ratio of 2.99 ± 0.16 were included. Area under the ROC curve (AUC) of AL/CR ratio for myopia detection (0.958 for AL/CR1, 0.956 for AL/CR2, 0.961 for AL/CR) was significantly larger than that of AL (0.919, all P < 0.001), while AUCs of the three were similar with different cutoffs (> 2.98, > 3.05, and > 3.02). When divided by age, the ROC curves of AL/CR ratio in 3- to 5-year-olds showed no significance or low accuracy (AUCs ≤ 0.823) in both genders. In ≥ 6-year-olds, the accuracies were promising (AUCs ≥ 0.883, all P < 0.001), the cutoffs basically increased with age (from > 2.93 in 6-year-olds to > 3.07 in 18-year-olds among girls, and from > 2.96 in 6-year-olds to > 3.07 in 18-year-olds among boys). In addition, boys presented slightly larger cutoffs than girls in all ages except for 16 and 18 years old. For children aged 3-5 years, AL/CR ratio or AL combined with NCAR increased AUC to > 0.900. CONCLUSION: AL/CR ratio provided the best prediction of myopia with age-dependent cutoff values for all but preschool children, and the cutoffs of boys were slightly larger than those of girls. For preschool children, AL/CR ratio or AL combined with NCAR is recommended to achieve satisfactory accuracy. AL/CR ratio calculated by two meridians showed similar predictive power but with different cutoffs.


Assuntos
Miopia , Refração Ocular , Pré-Escolar , Humanos , Masculino , Feminino , Adolescente , Criança , Testes Visuais , Rádio (Anatomia) , Miopia/diagnóstico , Córnea , Midriáticos
11.
Br J Ophthalmol ; 108(3): 405-410, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-36787996

RESUMO

BACKGROUND/AIMS: We aim to explore the effect of sympathetic nervous system (SNS) on choroid thickness (ChT) and axial length (AL). METHODS: Students of grade 2 and 3 from a primary school were included and followed for 1 year. Visual acuity, refraction, AL and ChT were measured. Morning urine samples were collected for determining SNS activity by analysing concentrations of epinephrine, norepinephrine and dopamine using the liquid chromatography-tandem mass spectrometry. The most important factor (factor 1) was calculated using factor analysis to comprehensively indicate the SNS activity. RESULTS: A total of 273 students were included, with an average age of 7.77±0.69 years, and 150 (54.95%) were boys. Every 1 µg/L increase in epinephrine is associated with 1.60 µm (95% CI 0.30 to 2.90, p=0.02) decrease in average ChT. Every 1 µg/L increase in norepinephrine is associated with 0.53 µm (95% CI 0.08 to 0.98, p=0.02) decrease in the ChT in inner-superior region. The factor 1 was negatively correlated with the ChT in the superior regions. Every 1 µg/L increase in norepinephrine was associated with 0.002 mm (95% CI 0.0004 to 0.004, p=0.016) quicker AL elongation. The factor 1 was positively correlated with AL elongation (coefficient=0.037, 95% CI 0.005 to 0.070, p=0.023). CONCLUSIONS: We hypothesised that chronic stress characterised by elevated level of the SNS, was associated with significant increase in AL elongation, probably through thinning of the choroid.


Assuntos
Refração Ocular , Tomografia de Coerência Óptica , Masculino , Criança , Humanos , Feminino , Tomografia de Coerência Óptica/métodos , Corioide , Norepinefrina , Epinefrina , Comprimento Axial do Olho
12.
Graefes Arch Clin Exp Ophthalmol ; 262(1): 3-17, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37231280

RESUMO

Given the high incidence and prevalence of myopia, the current healthcare system is struggling to handle the task of myopia management, which is worsened by home quarantine during the ongoing COVID-19 pandemic. The utilization of artificial intelligence (AI) in ophthalmology is thriving, yet not enough in myopia. AI can serve as a solution for the myopia pandemic, with application potential in early identification, risk stratification, progression prediction, and timely intervention. The datasets used for developing AI models are the foundation and determine the upper limit of performance. Data generated from clinical practice in managing myopia can be categorized into clinical data and imaging data, and different AI methods can be used for analysis. In this review, we comprehensively review the current application status of AI in myopia with an emphasis on data modalities used for developing AI models. We propose that establishing large public datasets with high quality, enhancing the model's capability of handling multimodal input, and exploring novel data modalities could be of great significance for the further application of AI for myopia.


Assuntos
COVID-19 , Miopia , Oftalmologia , Humanos , Inteligência Artificial , Pandemias , COVID-19/epidemiologia , Miopia/diagnóstico , Miopia/epidemiologia , Miopia/terapia
13.
BMC Microbiol ; 23(1): 286, 2023 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-37803284

RESUMO

BACKGROUND: Microbiome changes on the ocular surface may cause dry eyes. A metagenome assay was used to compare the microbiome composition and function of the ocular surface between diabetic children and adolescents with dry eye, diabetic children and adolescents without dry eye, and normal children. MATERIALS AND METHODS: Twenty children and adolescents aged 8 to 16 with diabetes were selected from the Shanghai Children and Adolescent Diabetes Eye Study. Ten healthy children and adolescents belonging to the same age group were selected from the outpatient clinic during the same period. The participants were classified into the dry eye group (DM-DE group, n = 10), the non-dry eye group (DM-NDE group, n = 10) and the normal group (NDM group, n = 10). A conjunctival sac swab was collected for metagenomic sequencing, and the relationship between the microbiome composition and functional gene differences on the ocular surface with dry eye was studied. RESULTS: The classification composition and metabolic function of the microorganisms on the ocular surface of children in the 3 groups were analyzed. It was found that children's ocular microbiota was composed of bacteria, viruses and fungi. There were significant differences in α diversity and ß diversity of microbial composition of ocular surface between DM-DE group and NDM group(P<0.05). There were significant differences in α and ß diversity of metabolic pathways between the two groups(P<0.05). The functional pathways of ocular surface microorganisms in diabetic children with dry eyes were mainly derived from human disease, antibiotic resistance genes, carbohydrate, coenzyme and lipid transport and metabolism-related functional genes; In normal children, the functional pathways were mainly derived from replication, recombination, repair, signal transduction and defense-related functional genes. CONCLUSION: The DM-DE group have unique microbial composition and functional metabolic pathways. The dominant species and unique metabolic pathways of the ocular surface in the DM-DE group may be involved in the pathogenesis of dry eye in diabetic children.


Assuntos
Diabetes Mellitus , Síndromes do Olho Seco , Microbiota , Humanos , Adolescente , Criança , Metagenoma , China , Diabetes Mellitus/genética , Microbiota/genética
14.
Br J Ophthalmol ; 2023 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-37709362

RESUMO

BACKGROUND: This research aims to generate normative values of hyperopia reserve and refractive progression as effective tools to estimate the risk of myopia. METHODS: A 1-year follow-up study was conducted among Chinese children and adolescents aged 3-16 years selected from schools and kinder gardens using cluster sampling. All participants underwent examinations including visual acuity, axial length and cycloplegic autorefraction (1% cyclopentolate). Percentiles of spherical equivalent (SE) were calculated using Lambda-Mu-Sigma (LMS) method. Age-specific refractive progression and hyperopia reserve were determined by backward calculation. RESULTS: Of 3118 participants, 1702 (54.6%) were boys with a mean baseline age of 7.30 years. The 50th percentile of SE estimated by LMS decreased from 1.04 D at 3 years to -2.04 D at 16 years in boys, while from 1.29 D to -2.81 D in girls. The 1-year refractive progression of myopes (0.81 D) was greater than that of non-myopes (0.51 D). The normative value of hyperopia reserve was 2.64 (range: 2.40 D-2.88 D) at 3 years and -0.35 (range: -0.50 to -0.17) D at 16 years, with the maximum progression of 0.35 D at the age of 6 years. CONCLUSION: Age-specific normative values of hyperopia reserve and yearly myopic shift in children and adolescents aged 3-16 years were provided, helping identify and monitor myopia and giving prevention in advance.

15.
Ophthalmic Res ; 66(1): 1139-1147, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37579732

RESUMO

INTRODUCTION: Diabetes mellitus may compromise the vasculature of the iris, thereby leading to severe vision-threatening complications. This study aimed to investigate differences in iris blood flow indices between pediatric type 1 diabetes mellitus (T1DM) patients and adult type 2 diabetes mellitus (T2DM) patients. METHODS: This was a cross-sectional study. Pediatric T1DM patients and healthy children were members of the Shanghai Children and Adolescent Diabetes Eye (SCADE) cohort who visited Shanghai Eye Hospital in February 2022. The adult T2DM patients and healthy adults were patients who visited Shanghai General Hospital from October 2021 to January 2022. Iris OCTA was acquired through a Cirrus HD-OCT 5000 angiography system (Carl Zeiss Meditec, Inc.). A unique iris OCTA quantification method was used, and the vessel area density (VAD) and vessel skeleton density (VSD) were obtained. The area from the pupillary margin to the corneoscleral limbus was taken as the whole iris blood flow index, and the inner third near the pupillary margin of the whole iris was taken as the pupillary margin blood flow index. RESULTS: This study enrolled 34 pediatric T1DM patients, 34 age-matched healthy children, 34 adult T2DM patients, and 34 age-matched healthy adults. The whole iris and pupillary margin VAD and VSD of the pediatric T1DM patients were not different from those of healthy children. The whole iris VAD and VSD of the adult T2DM patients were lower than those of healthy adults, and the pupillary margin VAD and VSD were the same in these two groups. Compared with adult T2DM patients, pediatric T1DM patients had higher whole iris VAD and VSD and lower pupillary margin VAD and VSD values, all with statistical significance. Among diabetic patients, age, BMI, and glycated hemoglobin level were negative independent influencing factors for whole iris VAD and VSD, and age was a positive influencing factor for pupillary margin VAD and VSD. CONCLUSION: There are diverse alterations in iris vessel density and blood flow distribution between pediatric T1DM patients and adult T2DM patients.


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Adulto , Adolescente , Humanos , Criança , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 2/complicações , Estudos Transversais , China/epidemiologia , Iris
16.
J Cataract Refract Surg ; 49(10): 1043-1048, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37488748

RESUMO

PURPOSE: To develop deep learning-based networks for the diagnosis of diabetic retinopathy (DR) with cataracts based on infrared fundus images. SETTING: Shanghai General Hospital, Shanghai Eye Disease Prevention & Treatment Center, Shanghai, China. DESIGN: Development and evaluation of an artificial intelligence (AI) diagnostic method. METHODS: A total of 10 665 infrared fundus images from 4553 patients with diabetes were used to train and test the model. For image quality assessment, left and right eye classification, DR diagnosis and grading, and segmentation of 3 DR lesions, an end-to-end software using EfficientNet and UNet was developed. The accuracy and performance of the software in comparison to human experts was evaluated. RESULTS: The model achieved an accuracy of 75.31% for left and right eye classification, 100% for DR grading and diagnosis tasks, and 73.67% for internal test set, with corresponding areas under the curve (AUCs) of 0.88, 1.00, and 0.89, respectively. For DR lesion segmentation, the AUCs of hemorrhagic, microangioma, and exudative lesions were 0.86, 0.66, and 0.84, respectively. In addition, a contrast test of human-machine film reading confirmed the software's high sensitivity (96.3%) and specificity (90.0%) and consistency with the manual film reading group (κ = 0.869, P < .001). This easily deployable software generated reports quickly and promoted efficient DR screening with cataracts in clinical and community settings. CONCLUSIONS: AI-assisted software can perform automatic analysis of infrared fundus images and has substantial application value for the diagnosis of DR patients with cataracts.


Assuntos
Catarata , Aprendizado Profundo , Diabetes Mellitus , Retinopatia Diabética , Humanos , Retinopatia Diabética/diagnóstico , Inteligência Artificial , China , Fundo de Olho , Catarata/diagnóstico , Fotografação/métodos
17.
Front Endocrinol (Lausanne) ; 14: 1131993, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37334311

RESUMO

Objective: To study the differences in blood cellular communication network factor 1 (CCN1) levels between patients with diabetes mellitus (DM) and healthy individuals and to explore the relationship between CCN1 and diabetic retinopathy (DR). Methods: Plasma CCN1 levels were detected using ELISA in 50 healthy controls, 74 patients with diabetes without diabetic retinopathy (DM group), and 69 patients with diabetic retinopathy (DR group). Correlations between CCN1 levels and age, body mass index, mean arterial pressure, hemoglobin A1c, and other factors were analyzed. The relationship between CCN1 expression and DR was explored using logistic regression after adjusting for confounding factors. Blood mRNA sequencing analysis was performed for all subjects, and the molecular changes that may be related to CCN1 were explored. The retinal vasculature of streptozotocin-induced diabetic rats was examined using fundus fluorescein angiography; in addition, retinal protein expression was examined using western blotting. Results: Plasma CCN1 levels in patients with DR were significantly higher than in the control and DM groups; however, no significant differences were observed between healthy controls and patients with DM. CCN1 levels negatively correlated with body mass index and positively correlated with the duration of diabetes and urea levels. It was observed that high (OR 4.72, 95% CI: 1.10-20.25) and very high (OR 8.54, 95% CI: 2.00-36.51) levels of CCN1 were risk factors for DR. Blood mRNA sequencing analysis revealed that CCN1-related pathways were significantly altered in the DR group. The expression of hypoxia-, oxidative stress-, and dephosphorylation-related proteins were elevated, while that of tight junction proteins were reduced in the retinas of diabetic rats. Conclusion: Blood CCN1 levels are significantly elevated in patients with DR. High and very high levels of plasma CCN1 are risk factors for DR. Blood CCN1 level may be a potential biomarker for diagnosis of DR. The effects of CCN1 on DR may be related to hypoxia, oxidative stress, and dephosphorylation.


Assuntos
Diabetes Mellitus Experimental , Retinopatia Diabética , Animais , Ratos , Diabetes Mellitus Experimental/metabolismo , Retinopatia Diabética/diagnóstico , Retinopatia Diabética/etiologia , Retinopatia Diabética/metabolismo , Retina/metabolismo , Fatores de Risco , RNA Mensageiro/metabolismo
18.
J Cataract Refract Surg ; 49(8): 858-863, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37350758

RESUMO

PURPOSE: To explore clinical indicators to predict perceived pain during second-eye phacoemulsification surgery in patients with bilateral cataracts. SETTING: Shanghai General Hospital, China. DESIGN: A case‒control study and a prospective cohort study. METHODS: Patients with age-related cataract who underwent first-eye or second-eye uneventful phacoemulsification surgery were enrolled. Before surgery, ocular examination results, including vessel area density (VAD) and vessel skeleton density (VSD), obtained by optical coherence tomography angiography examination of the iris were performed. Patients completed a visual analog scale pain survey 3 times postoperatively: 1 hour, 3 hours, and 24 hours postoperatively. RESULTS: 70 patients were enrolled in the case‒control study, and the pain scores of the second-eye surgery group under local anesthesia were significantly greater than those of the first-eye surgery group ( P = .0005). Preoperative iris VAD in the second-eye group affected perioperative pain scores ( P = .0047). The optimal cutoff value of VAD was 0.2167 with a specificity of 76% and a sensitivity of 62%. In the prospective cohort study, 124 patients were included in the second-eye group. Preoperative iris VAD ( P = .0361) and the time interval ( P = .0221) were independent factors for second-eye surgery pain. Combined with preoperative iris VAD and surgical interval, the negative predictive value and positive predictive value were 0.95 and 0.29 for predicting moderate pain or above, the sensitivity and specificity were 0.97 and 0.23, respectively. CONCLUSIONS: The combination of iris VAD and the time interval between both eye surgeries can be an effective method to predict the timing of the second-eye cataract surgery and to avoid intraoperative pain.


Assuntos
Extração de Catarata , Catarata , Facoemulsificação , Humanos , Estudos Prospectivos , Estudos de Casos e Controles , China , Iris , Extração de Catarata/métodos , Dor , Percepção da Dor
19.
Kaohsiung J Med Sci ; 39(9): 916-926, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37338034

RESUMO

The blood-retinal barrier (BRB), homeostasis, neuronal integrity, and metabolic processes are all directly influenced by Müller cells, the most important retinal glial cells. We isolated primary Müller cells from Sprague-Dawley (SD) neonatal rats and treated them with glucose at varying doses. CCK-8 was used to quantify cellular viability, and a TUNEL assay was performed to detect cell apoptosis. ELISA, immunofluorescence, and western blotting were used to assess cAMP/PKA/CREB signaling, Kir4.1, AQP4, GFAP, and VEGF levels, respectively. H&E staining was used to examine histopathological alterations in diabetic retinopathy (DR)-affected retinal tissue in rats. As glucose concentration increases, gliosis of Müller cells became apparent, as evidenced by a decline in cell activity, an increase in apoptosis, downregulation of Kir4.1 level, and overexpression of GFAP, AQP4, and VEGF. Treatments with low, intermediate, and high glucose levels led to aberrant activation of cAMP/PKA/CREB signaling. Interestingly, blocking cAMP and PKA reduced high glucose-induced Müller cell damage and gliosis by a significant amount. Further in vivo results suggested that cAMP or PKA inhibition significantly improved edema, bleeding, and retinal disorders. Our findings showed that high glucose exacerbated Müller cell damage and gliosis via a mechanism involving cAMP/PKA/CREB signaling.


Assuntos
Diabetes Mellitus , Retinopatia Diabética , Ratos , Animais , Retinopatia Diabética/genética , Ratos Sprague-Dawley , Fator A de Crescimento do Endotélio Vascular/genética , Gliose , Glucose/farmacologia
20.
Br J Ophthalmol ; 2023 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-37290823

RESUMO

AIMS: To investigate myopic maculopathy in Chinese children with high myopia and its association with choroidal and retinal changes. METHODS: This cross-sectional study included Chinese children aged 4-18 years with high myopia. Myopic maculopathy was classified by fundus photography and retinal thickness (RT) and choroidal thickness (ChT) in the posterior pole were measured by swept-source optical coherence tomography. A receiver operation curve was used to determine the efficacy of fundus factors in classifying myopic maculopathy. RESULTS: In total, 579 children aged 12.8±3.2 years with a mean spherical equivalent of -8.44±2.20 D were included. The proportions of tessellated fundus and diffuse chorioretinal atrophy were 43.52% (N=252) and 8.64% (N=50), respectively. Tessellated fundus was associated with a thinner macular ChT (OR=0.968, 95% CI: 0.961 to 0.975, p<0.001) and RT (OR=0.977, 95% CI: 0.959 to 0.996, p=0.016), longer axial length (OR=1.545, 95% CI: 1.198 to 1.991, p=0.001) and older age (OR=1.134, 95% CI: 1.047 to 1.228, p=0.002) and less associated with male children (OR=0.564, 95% CI: 0.348 to 0.914, p=0.020). Only a thinner macular ChT (OR=0.942, 95% CI: 0.926 to 0.959, p<0.001) was independently associated with diffuse chorioretinal atrophy. When using nasal macular ChT for classifying myopic maculopathy, the optimal cut-off value was 129.00 µm (area under the curve (AUC)=0.801) and 83.85 µm (AUC=0.910) for tessellated fundus and diffuse chorioretinal atrophy, respectively. CONCLUSION: A large proportion of highly myopic Chinese children suffer from myopic maculopathy. Nasal macular ChT may serve as a useful index for classifying and assessing paediatric myopic maculopathy. TRIAL REGISTRATION NUMBER: NCT03666052.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...